Question #1
Robert, I have a bill from Santa Clarita Water Company telling me that I’m wasting water, telling me to check everything around the house, which I’ve done.
One of the things that they’ve told me to check is if my toilets are running. I look at my toilets and I don’t see anything running, but they are telling me that it is probably the culprit.
How do I know, in looking at it, if it’s running or not? How do I tell? I am on a fixed income and need to know what do to on my own, without calling for help. Merry H.
Answer #1
Merry, what you do is just go down to the market, buy some food coloring, some dye – red or yellow, preferably red because it shows up the most.
You put the dye in the water closet, which is the storage tank on top of the toilet where you can take the lid off. Drop 10 drops of dye in there and stir it up.
If the toilet is not leaking, you will not see any dye make its way into the bowl. If you do see dye in the bowl, that means that the flapper is leaking and allowing water to get into the toilet.
Without the dye, you may not see the leak if you’re not looking under the rim very closely. If you do see red water in the bowl, then you know the flapper is bad.
Turn the angle stop off that is on the wall under the toilet; this is the shut-off valve. This turns the water off to the toilet.
Reach into the water closet. Take the flapper off and take it to the local hardware store; ask the associate to match it up for you.
Install the new one. This is a very simple task. If your flapper is more than two years old, I would do this automatically, as they wear out.
This will ensure that this flapper is going to seat properly and not allow water to leak into the bowl, thus wasting water.
Question #2
Robert, I have no power at the receptacles in my bathroom and kitchen, and it’s driving me crazy. I’m told that there’s a GFI and that’s why the thing isn’t working. I’m kind of handy, and for the life of me I can’t find a GFI anywhere inside the house. Jim T.
Answer #2
Jim, anywhere there is a “wet” location (anywhere outside is considered a “wet” location; inside a “wet” location would be a sink, laundry room, lavatory), the receptacle must be a GFI.
Depending on the size of the house (you didn’t mention the size of your home), you may only have one GFI. If you can’t find your GFI inside or anywhere in your electrical box (sometimes there will be a GFI breaker that you can replace; make sure to check this), go to your patio and you’ll no doubt have a GFI receptacle out there.
I’m not an advocate of giving electrical advice in the newspaper, but if you’re a handy person and you’re going to do it, just make sure that you have an electrical tester before you start.
Make sure that you turn your power off. Turn the breakers off. My recommendation is that if you’re not familiar with this, turn the power to the whole house off so that you are safe.
Prior to this, though, make sure that your computers and all electronics are prepared for this.
Go back out and test for power with your electrical tester, making sure
there is no power going to this circuit.
Take the GFI out, go to your local hardware store and have it matched up. It will be a 15 or 20 amp. Make sure you size it up to that as well, double check, and then return and begin the reverse process for installation.
Turn one breaker on at a time, making sure that you previously prepared all electronics so that they aren’t subject to a spike in power.
Turn everything back on, and good luck.
Robert Lamoureux has 38 years of experience as a general contractor, with separate licenses in electrical and plumbing contracting. He owns IMS Construction Inc. in Valencia. His opinions are his own, not necessarily those of The Signal. Opinions expressed in this column are not meant to replace the recommendations of a qualified contractor after that contractor has made a thorough visual inspection.