Robert Lamoureux: There’s no need for hot-mop pans

Robert,

I’m remodeling my bathroom and acting as my own general contractor. One of the things I’m doing is replacing the bathtub with a shower. I understand I need to put in a hot mop pan. Is there an alternative to a pan? Thank you,

Jeff B.

Hi Jeff,

There are liners made of rubber you can use instead of a hot-mop pan. With these, you don’t need a hot mop, and so you don’t have the smell. You just lay it out and fit it into the bottom of the pan. It’s very easy to do and is a do-it-yourself project.

When you get into a hot-mop situation, you need somebody with a kettle, hot mop, tar paper — the whole gamut.

As I understand, the rubberized system is better than the hot mop because it doesn’t crack. The hot mop, just like roofing tar, can crack in the future and that’s how you get pan leaks.

You’ll want to raise the floor on the perimeters. Keep in mind you’ll need a 1/4” fall per running foot. The outside of the shower gets raised so that it slopes down to the drain. Do that with a mortar bed, then put the rubberized membrane on top.

Hi Robert,

I serve on our HOA board, and we’re having drains put into our garage area from our upstairs courtyard. The plumbers are telling us we can’t use the ABS pipe. They say it has to be metal, which is more expensive, but for some reason, they don’t want to give us the reason why.

James D.

Hi James,

That information is correct. In a fire, both ABS and PVC would burn.

The toxic fumes from the plastics can kill people.

So, the reason for cast iron in a garage is because if one of the cars were to catch fire, the plastic is not only toxic, but it would melt, and could burn people.

Any commercial-location drain line has to be in cast iron. That’s code.

Another reason is for cleaning purposes. The plumbing in restaurants, for example, often requires snaking, or running cable machines to clean out.

Plastic would wear out quickly, whereas cast iron has much better longevity.

Hi Robert,

I read your column all of the time. I have a pool and am gearing up for the summer. There was a reminder to get my pool in order. I’ve got that gray putty between the pool bricks and concrete that needs to be replaced. What do I replace it with? I have already dug it out but I think the space is too deep. I put sand in there and it just vanished. I put in a whole bag and it’s still not filling up. Thank you for your time and any information you can provide. Thanks,

Ryan Y.

Hi Ryan,

That’s your Deck-O-Seal you’re talking about. It’s a joint sealant or mastic — very strong stuff with a lot of elasticity to it.

This is applied between the coping stone and the pool deck to keep the water out. It acts like a shock absorber so when the deck gets hot and expands your coping is not pushed into the pool. If the sealant fails or is not properly maintained, water can cause your decking to crack and could damage the coping.

If you’re losing that much sand in the joint, then the dirt underneath has eroded away. This is a common problem. Many times, when you remove the Deck-O-Seal, you’ll find the dirt underneath has shifted and settled.

Or, it can be caused from not having enough joint sealant which allows water to wash out the fill. This can give you a large cavity — I’ve seen up to 1-foot deep. You need to fill those cavities, before you need a root canal.

You don’t want to fill that open space with sealant, which would get very expensive. The trick is to get some backer rod, which is available from any pool supply house. This is a round styrofoam rod. Just lay it out in the gap about 1/2” down.

Once you have this in place, all the way around the pool, then you mix up the Deck-O-Seal, which is a two-part epoxy. Mix the product really well, and put it in the enclosed squirt bottle. Then just fill in the gap directly on top of the backer rod.

This sealant is really strong stuff, and will keep all the years of splashing and rains from undermining the dirt around the bond beam.

You’ll want to make sure that all of the areas are really clean beforehand so you’ll get a good bond. Some folks like to leave it in its natural state, or you can broadcast some silica sand over it to give a bit of a texture as opposed to a glazed look.

Once it dries, just brush the excess silica sand off and you’re good to go.

Robert,

What do you think of this new procedure of “rebath?” What would be the pros and cons?

Curt W.

Hi Curt,

The rebath system is just an economical method of resurfacing your tub and shower. The concept is very similar to having your kitchen cabinets re-faced as opposed to replaced. The existing substructure is used and given a new exterior.

The pros are that this procedure is much less expensive and faster than the traditional methods of remodeling. The cons might be the quality of the materials used.

I have personally not used this type of service, but if quality products and professional installers are used, I can’t think of anything wrong with this type of service.

One thing to keep in mind is proper maintenance of your newly rebathed tub. Once the tub has been re-glazed, be sure to follow the recommendations on the type of non-abrasive cleansers to be used.

Using any of the traditional cleaners on a re-glazed tub will cause scratches and stains.

We have designed a custom, full-color The Signal/Your Home Improvements T-shirt we will give you if we answer your question. The T-shirt is available to be picked up at our office.

Robert Lamoureux has 25 years experience as a general contractor, with separate licenses in electrical and plumbing contacting. He owns IMS Construction Inc. in Valencia. His opinions are his own, and not necessarily those of The Signal. Opinions expressed in this column are not meant to replace the recommendations of a qualified contractor, after that contractor has made a thorough visual inspection. Send your questions to [email protected] .

← Back to 2011

About this record

How it was held, read and classified

Record details

Morris ID
54039
System
Morris section CMS (/section/…/article/… and /archives/…)
Reading copy
signalscv.com
Chosen by: only copy held. On this copy: words 1,090 (e-mail addresses counted as one token); reader comments 0 (counted, not reproduced here); images 0.
Extracted by
section_cms:articlebody_span
signal-extract/0.15 (2026-11-16)

Other copies (2)

Host
signalscv.com, under the old Morris system
http://www.signalscv.com:80/archives/44231/
Captured25 October 2013, 21:19:43 UTC
CaptureThe archive does not serve this capture as a facsimile; the text is extracted from it.
SHA-2568555bf0ebe73ac6d4d2cbc6d4af4aae30ff20c695643b98cf95c5bd5d6498935SHA-256 of the bytes the archive holds, recorded at intake. A SHA-1 of the same bytes, taken at the same time, equals the Wayback Machine’s own digest for this capture: QTOU5MTOXH4DZRN5HW3NARRDV2CHSMAP.
Holds alone
nothing: identical text, held under another of the paper's numbering systems (record m44231)
Host
the-signal.com
http://www.the-signal.com:80/archives/44231/
Captured2 May 2012, 20:08:47 UTC
CaptureThe archive does not serve this capture as a facsimile; the text is extracted from it.
SHA-2568f0207670d4dad9420f630ab0e3f998d2af2b6e03f1417d6029e865269410f59SHA-256 of the bytes the archive holds, recorded at intake. A SHA-1 of the same bytes, taken at the same time, equals the Wayback Machine’s own digest for this capture: MUHI2I2HDUBTV6FEJVKZS7CTG7VO5DTN.
Holds alone
nothing measured beyond the chosen copy

How it was classified

Label
clearly-local
Judgment
A machine’s (recorded as machine), kept as one so it can be revisited.
Classifier
signal-localclass/0.7 (2026-11-12)
Local signals
  • text:valley_names [1 distinct/1 mentions: Valencia]
  • byline:named_writer_no_wire_credit [Your Home Improvements]
National signals
none fired
Scores
local 3, national 0